Error 01 - 7000 Valve - Power OuttageUpdated 9 months ago

Error Code 01

If you see ERROR 01, then that's typically a simple fix and you can follow this guide. This error is usually from power outages. To prevent reoccurrence of Error Code 01 please add a uninterruptible power supply or UPS surge protector and plug the controller into it. 

Download Error Code 01 Guide.

Correcting Error Code 01 for 7000 XTR Valves

Depending on what the valve is set as will determine the settings.  The good news is with an Error Code 01 the original programming should not change.  It is always a good idea to check though.  You will need to enter master programming.  To do so press and hold the “Shift” button (the arrow that points left) and the up button together for approximately 5 seconds.  This can take a little longer sometimes so hold until the screen displays “System Type 4”.  If you can’t get the screen to change, you can remove the cover and that should make it so that it will change.  When System Type 4 is displayed press the extra cycle button (the diamond with the arrows around it). By pressing the extra cycle button that advances the programming.  Press the extra cycle button until the unit is back in service.  When Error Code 01 is corrected the screen will display service, and the time, as well as gallons remaining.  The blue light should be on.  If the green light is on and the valve enters regeneration, you held the extra cycle button down too long. If you do not want the unit to go through the entire regeneration process you can press the extra cycle button once the unit has started it’s countdown in each cycle and that will move the valve into service.  